Remote Panel Display (counter & Timer)

Front  view

Side corner view

Remote Counter Panel   (scroll down page for TIMER specifications)

Part No:    RCP-02, w/ software version 1.01

Physical:

3.2" (81.5mm) wide, 2.55" (65mm) high, 1.25" (32mm) deep

polycarbonate overlay over .058" thick aluminum face plate

.06" thick neoprene gasket seals to NEMA type 12 protection

supplied data cable is 30" (763mm) long

Display

2 line x 12 character super twist LCD, 40 degree viewing angle

character size is .25" (6.20mm) high, by .13" (3.2mm) wide

operating temperature range 0 to 50 deg. C. (32 to 120 deg. F.)

storage temperature range -20 to 70 deg. C. (-4 to 158 deg. F.)

Power Requirements

Power is supplied by the T6+ MCU via data cable, 5 volts max.

Performance

Each counter can be operated by any page, any number of times counting range is 0 to 59,999

Max. count speed is 100cps, which is limited MCU line execution

15 individual messages, containing 24 characters each

counter settings and messages are stored internally via nonvolatile eeprom which does not require battery backup.

OEM considerations:

Custom cable lengths for the RCP are available. Multiple RCP units can be "cloned" using a Program Transfer Module (part number PTM-02). This eliminates the need to setup each RCP individually. It will also store a copy of the RCP's program for backup.


Remote Timer Panel

Part No:  RTP-02, w/ software version 1.01

Physical:

3.2" (81.5mm) wide, 2.55" (65mm) high, 1.25" (32mm) deep

polycarbonate overlay over .058" thick aluminum face plate

.06" thick neoprene gasket seals to NEMA type 12 protection

supplied data cable is 30" (763mm) long

Display

2 line x 12 character super twist LCD, 40 degree viewing angle character size is .25" (6.20mm) high, by .13" (3.2mm) wide

operating temperature range 0 to 50 deg. C. (32 to 120 deg. F.)

storage temperature range -20 to 70 deg. C. (-4 to 158 deg. F.)

Power Requirements

Power is supplied by the T6+ MCU via data cable, 5 volts maximum

Performance

Each timer can be operated by any page, any number of times timing range is .01 to 49,999.90 seconds in 10ms resolution

Timing accuracy is + 3ms repeatability

15 individual messages, containing 24 characters each

Timer settings and messages are stored internally via nonvolatile eeprom which does not require battery backup.

OEM considerations

Custom cable lengths for the RTP are available. Multiple RTP units can be "cloned" using a Program Transfer Module (part number PTM-02). This eliminates the need to setup each RTP individually. It will also store a copy of the RTP's program for backup.

Go to specifications directory.

Go to price list page.